FEATURES
Sturdy metal housing
42 MHz bandwidth: 1680 tunable UHF
frequencies for interference-free reception
Enhanced frequency bank system with up
to 24 compatible frequencies
Ethernet port for connecting to the Wire-
less Systems Manager (WSM) software for
control via computer – this delivers a good
overview of monitoring and professio-
nal data management for multi-channel
systems
High-quality true diversity reception
Pilot tone squelch for eliminating RF inter-
ference when transmitter is turned off
Automatic frequency scan feature
searches for available frequencies
Enhanced AF frequency range
Wireless synchronization of transmitter
parameter from receiver
User-friendly menu operation with more
control options
Illuminated graphic display, receiver also
shows transmitter settings
Auto-Lock function avoids accidental
changing of settings
HDX compander for crystal-clear sound
Receiver shows transmitter battery
indicatation in 4 steps
Integrated Equalizer and Soundcheck mode
Wide range of accessories adapts the
system to any requirement
Optimized PLL synthesizer and
microprocessor technology
Sennheiser understands that the more self-reliant a device is, the more artistic
freedom there is to enjoy. With this in mind, this new receiver has a built-in Ether-
net port for remote PC monitoring and setup with Sennheiser’s Wireless System
Manager software. This receiver’s wireless sync function makes it a breeze to link
up any G3 transmitter with the unit. In addition, it has a large back-lit graphic
display where receiver and transmitter information can be easily seen even on the
darkest of stages.
TECHNICAL DATA
Modulation ...............................................................wideband FM
Frequency ranges.................................................... 516 558, 566 608, 626 668,
734–776, 780 822, 823 865 MHz
Receiving frequencies ............................................ 1,680 frequencies, tuneable in steps
of 25 kHz
20 frequency banks, each with
up to 24 factory-preset channels,
intermodulation-free
6 frequency banks with up to 24
user programmable channels
Switching bandwidth .............................................42 MHz
Nominal/peak deviation .......................................± 24 kHz/± 48 kHz
Receiver principle ....................................................true diversity
Sensitivity (with HDX, peak deviation) .............< 2 µV for 52 dBA rms S/N
Adjacent channel rejection ...................................typ. 75 dB
Intermodulation attenuation ...............................typ. 70 dB
Blocking ..................................................................... 75 dB
Squelch ...................................................................... Off, 5 to 25 dBµV,
adjustable in steps of 2 dB
Pilot tone squelch ...................................................can be switched off
Antenna inputs........................................................2 BNC sockets, 50 Ohm
Compander system .................................................Sennheiser HDX
EQ presets
Preset 1: “Flat”
Preset 2: “Low Cut” ................................................−3 dB at 180 Hz
Preset 3: “Low Cut/High boost” .......................... −3 dB at 180 Hz
+6 dB at 10 kHz
Continued on page 2
EM 300 G3 Rack-mount receiver
Page view 0
1 2 3 4

Summary of Contents

Page 1 - EM 300 G3 Rack-mount receiver

FEATURESSturdy metal housing 42 MHz bandwidth: 1680 tunable UHF frequencies for interference-free receptionEnhanced frequency bank system with

Page 2

EM 300 G3 Rack-mount receiverARCHITECT’SSPECIFICATIONSThe rack-mount receiver with true diversity technology shall be for use with a companion transmi

Page 3

EM 300 G3 Rack-mount receiverCONNECTIVITYDIMENSIONS213+

Page 4

PRODUCT VARIANTSEM 300 G3-A-EU – Frequency range 516...558 MHz / Power supply unit EU Cat. No. 503131EM 300 G3-A-US – Frequency range 516...558 MHz