Mounting and installing the products
24 | SpeechLine IS microphone series
C
) Ceiling-mounting a ME 3x microphone
Once you have chosen a position fo
r the product (see page 16):
왘 Remove the ceiling panel or the wooden boar
d and place it on a surface
that is suitable for drilling.
왘 Drill a hole with a diameter of 2
4 mm through the mounting surface
(plate thickness 10 mm - 65 mm).
왘 Insert the table mount into the drilled hole.
왘 Connect the XLR connector of the MZC 30 cable to the corresponding
so
cket of the MZT 30 table mount.
왘 Guide the cable through the MZH 3
0 metal ceiling hanger.
왘 Tightly screw one of the microphone heads onto the special coax socket
of t
he cable in order to ensure a reliable ground connection.
왘 Connect a suitable cable (see page 26), lay the cable
and remount the
ceiling panel or wooden board.