Steps for Auto Tuning evolution wireless G3 Systems
1. On the receiver, press SET to enter menu. Press up/down buttons to select “Easy Setup”. Press SET
and choose “Scan New List.” Press SET to start scan.
2. After the scan is completed the receiver will suggest a BANK to choose with the most free channels.
Press SET. Now select a channel using the up/down arrows and press SET to confirm. The receiver will
say “STORED.”
3. Tap the POWER button to exit the menu. The frequency chosen will be displayed. You should see zero
RF activity on the meter (meaning you are on a free channel).
4. Power up the transmitter you wish to pair with the receiver. Become familiar where the infrared (IR)
window is located. On a G3 handheld transmitter, the window is located on the display. On a body-
pack transmitter, it is located under the flap just to the right of the ON/OFF button.
5. Press the “SYNC” button on the front of the receiver and the receiver will enter SYNC mode. Simply
hold the handheld or bodypack IR window facing the left side of the receiver display about 1” to 2
away.
6. If the SYNC is successful, you should see a check mark on the receiver screen. If you see an “X”, it
indicates the sync failed and you should repeat step 5.
7. After a successful SYNC, you should see the frequency match on both the receiver and transmitter.
8. If setting up another system in the same frequency range (A/B/G), you can repeat the process from
Step 1. Just be sure to choose the same BANK number as you did in step 2 to ensure compatible
operation, and a different channel number.