Technical data
Casing metal diecast casing / light chromium plating
53 x 60 x 17 mm
Battery compartment integrated, for 2 AAA size cells with
reverse battery protection
Frequency range 450 - 960 MHz
Switching bandwidth 24 MHz
RF output power typ. 30 mW
Frequency stability ± 10 ppm
Spurious emission < 4 nW
Modulation FM
Nominal / peak deviation ± 40 kHz / ± 56 kHz
Compander system Sennheiser HiDyn plus
TM
Input sensitivity max. 49 mV
rms
= -24 dBu
for nominal deviation / 1 kHz AF switchable in 5 steps of 8 dB
max. input voltage 1.55 V
rms
Current consumption 115 mA / 2.4 V
AF frequency response 60 Hz - 20 kHz
Signal-to-noise ratio 110 dB(A)
rms
THD < 0.3% at nominal deviation / 1 kHz
Connections AF: 3-pin Lemo; RF: special co-ax Lemo
Weight with batteries 130 g
Operating time with primary cells AAA size alkaline batt. (IEC LR 03) = approx. 7 h
Operating time with recharg. batt. 700 mAh per cell (IEC LR 03) = approx. 5.5 h