Operation with systems of the
evolution wireless G2 series
When using receivers of the evolution wireless G2 series, there are three
operating modes:
1. “Single Device” operating mode:
one NET 1 with up to 10 receivers
2. “Master/Slave” operating mode:
two NET 1 with up to 20 receivers
3. “Remote” operating mode:
up to five NET 1 connected to a PC with up to 50 receivers.
The connected receivers may well have different frequency ranges.
Preparing the frequency preset scan
With the frequency preset scan, the NET 1 searches for free channels for
multi-channel operation (refer to the instructions for use of the evolution
wireless G2 receivers).
Switched-on transmitters that are to be configured via the NET 1 interfere
with the frequencies preset scan because their frequencies used are not
displayed as being “free”.
Switch off all transmitters that are to be configured via the NET 1.
Leave all transmitters switched on that are not to be configured via the
NET 1.
“Single Device” operating mode
The NET 1 selects one receiver from each of the frequency ranges to perform
the frequency preset scan. The frequencies of the selected channel bank are
assigned to the connected receivers of this frequency range. Subsequently,
the frequencies are transferred to the corresponding transmitters.
Performing the frequency preset
Press and hold the MODE button on the NET 1. The NET 1 selects one
receiver per frequency range. The “CHANNEL” LED assigned to this
receiver lights up.
Start the frequency preset scan by pressing the channel button
assigned to this receiver.
The corresponding “CHANNEL” LED and the yellow “SCAN” LED flash
slowly.
The results of any prior frequency preset scan are overwritten.