Sennheiser SDC 8200 SYS-M - 06-10 Specifications Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
Spec. No. 1095
(rev. 12.05.12)
pg. 2 of 2
©2012 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069. Phone–800.325.9660
Fax—636.257.6606. Lowell makes every effort to provide accurate information while reserving the right to
change specifications and/or improve manufacturing methods without notification. (lowellmfg.com)
TOP CLOSURE PANELS
Maximum wire distances: 24-ga 20,000 ft. (approximately 3.5 miles); 22-ga. 31,200 ft.
(approx. 5.5 miles); 18-ga. 76,800 ft. (approx. 13.5 miles).
If required by local building code, facility usage,
or the Fire Marshal; the system switches can
be overridden and the system controlled by
contact closures provided by the fire alarm
panel or other control system. A maintained
contact between the “com” terminal and any of
the terminals shown here will provide the fol-
lowing functions.
Lock Off: A maintained contact between the
“COM” terminal and the “LOCK-OFF” terminal
will turn the system off and keep it off regard-
less of other switch activations. If the system is
already off, it will be kept off.
Lock On: A maintained contact between the
“COM” terminal and the “LOCK-ON” terminal
will turn the system on and keep it on regard-
less of other switch activations. If the system is
already on, it will be kept on.
Switch Lock: A maintained contact between
the “COM” terminal and the “SWITCH-LOCK”
terminal will lock the system in its current state,
either on or off, regardless of any other switch
activations.
Caution: Do not allow alarm system to make
more than one of the contacts described above
at the same time. Controller board damage
may result.
ALARM SYSTEM INTERFACE
120VAC 60Hz
20A 2400W
Unswitched 1 Switched 2 Switched
3
4
Switched
Includes 9-ft. cord with NEMA 5-20P plug.
Multiple RPC-series remote power control
units can be connected to outputs 5 and 6 (60
max. each, dependent upon limits of electrical
panel). Order RPC units separately.
Connect a maximum of 5 remote MOMENTARY
switches. Order switches separately.*
RPC TRIGGER CONNECTIONS REMOTE SWITCH CONNECTIONS
Four conductors (2 LED switch).
Three conductors (1 LED switch).
RPC-series remote
power controls.
Front
Rear
Panel is available with rocker or key-switch.
Red LED flashes when cycling down and remains
lit when system is off. Green LED flashes when
cycling up and remains lit when system is on.
Optional surge suppression function
with LEDs that indicate if there is full
or reduced protection.
Surge Suppression Surge Suppression Remote Trigger
Activated
Circuit Breaker 15A 1800W max
Unswitched
* See momentary switches:
Models with 2 LEDs: RPSB2-MP, RPSB2-MKP, RPSW2-MP,
RPSW2-MKP, RPSB2-MR, RPSB2-MKR
Models with 1 LED: RPSB-MP, RPSB-MKP, RPSW-MP,
RPSW-MKP, RPSB-MR, RPSB-MKR
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 87 88

Comments to this Manuals

No comments