Sennheiser EK 100 G3 Instruction Manual

Browse online or download Instruction Manual for Security access control systems Sennheiser EK 100 G3. Sennheiser EK 100 G3 Instruction manual [en] User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - 100 Series

100 SeriesInstruction manual

Page 2

Product overview8Overview of the displays of the SK 100 bodypack transmitterAfter switch-on, the bodypack transmitter displays the standard display “F

Page 3 - Contents

Product overview9Overview of the SKM 100 radio microphoneOperating elements쐃 Microphone head (interchangeable)쐇 Name and pick-up pattern of the micro-

Page 4 - Important safety instructions

Product overview10Overview of the displays of the SKM 100 radio microphoneAfter switch-on, the radio microphone displays the standard display “Frequen

Page 5 - Intended use of the system

Putting the devices into operation11Putting the devices into operationEM 100 receiverSetting up the receiver on a flat surfacePlace the receiver on a

Page 6 - The frequency bank system

Putting the devices into operation12Stacking receivers  Stack several receivers on top of each other.Connecting the rodantennasThe supplied rod anten

Page 7 - Product overview

Putting the devices into operation13Connecting the mains unitOnly use the supplied mains unit. It is designed for the receiver and ensures safe operat

Page 8 - EW100 G3

Putting the devices into operation14Charging the accupackTo charge the BA 2015 accupack: Insert the bodypack transmitter into the L 2015 charger (opt

Page 9

Putting the devices into operation15To detach the belt clip: Lift one side of the belt clip as shown in the diagram on the right-hand side. Press do

Page 10

Putting the devices into operation16Charging the accupackTo charge the radio microphone with the inserted BA 2015 accupack (optional accessory): Use

Page 11 - Operating elements

Using the devices17Using the devicesTo establish a transmission link, proceed as follows:1. Switch the receiver on.2. Switch a transmitter on.The tran

Page 13 - EM 100 receiver

Using the devices18To completely switch the receiver off: Disconnect the receiver from the mains by unplugging the mains unit from the wallsocket.SK

Page 14

Using the devices19To activate the RF signal:SKM 100 radio microphoneTo switch the radio microphone on (online operation):To switch the radio micropho

Page 15 - SK 100 bodypack transmitter

Using the devices20To switch the radio microphone on and to deactivate the RF signal on switch-on (offlineoperation):To activate the RF signal:Synchro

Page 16 - Charging the accupack

Using the devices21“ ” appears on the display panel of the receiver. “ ” also appears if:– no transmitter was found or the transmitter is not compatib

Page 17 - SKM 100 radio microphone

Using the devices22Muting the audio signal or deactivating the RF signalEM 100To mute the audio signal:To unmute the audio signal:SK 100The MUTE switc

Page 18 - Changing the microphone head

Using the devices23The current state of the muting function or the RF signal is displayed on the display panel ofthe bodypack transmitter.SKM 100You c

Page 19 - Using the devices

Using the devices24Selecting a standard displayEM 100SK 100 and SKM 100To select a standard display: Press the UP/DOWN button to select a standard di

Page 20

Overview of the operating menus25Overview of the operating menusEM 100When one of the standard displays is shown on the display panel, you can get int

Page 21

Overview of the operating menus26SK 100 and SKM 100Easy Setup Scans for unused frequency presets, releases and selects frequency presetsFrequency Pres

Page 22 - ew100 G3

Cleaning the devices27Cleaning the devicesEM 100 Before cleaning, disconnect the device from the mains.  Use a slightly damp cloth to clean the rece

Page 23

Contents1ContentsImportant safety instructions ...

Page 24

Cleaning the devices28To clean the radio microphone’s sound inlet basket (MMD 835-1, MMD 845-1, MMD 935-1,MMD 945-1, MME 865-1): Unscrew the upper so

Page 25

Cleaning the devices29SK 100 and SKM 100RF signal available, no audio signal, “MUTE” appears on the display panelTransmitter is muted (“MUTE”)or trans

Page 26 - B.Ch: 20.24

Cleaning the devices30If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions,please

Page 27 - CAUTION!

Specifications31SpecificationsEM 100RF characteristicsModulation wideband FMReceiving frequency ranges 516–558, 566–608, 626–668, 734–776, 780–822, 82

Page 28

Specifications32In compliance with (EM)Approved byIn compliance with Certified by cCSAus KL, 60065, CSA.SK 100 and SKM 100Europe:USA:EMC EN 301489-1/-

Page 29 - Cleaning the devices

Specifications33In compliance with (SK and SKM)Approved by (SK)Approved by (SKM)AF characteristicsCompander system Sennheiser HDXAF frequency response

Page 30 - If a problem occurs

Specifications34Microphones (SK 100)Microphone heads (SKM 100)Polar diagrams and frequency response curves of the microphone heads (SKM 100)ME 2 ME 3

Page 31 - SK 100 and SKM 100

Manufacturer Declarations35Manufacturer DeclarationsWarrantySennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this product.For

Page 32

Manufacturer Declarations36Statements regarding FCC and Industry Canada These devices comply with Part 15 of the FCC Rules and with RSS-210 of Industr

Page 34

Important safety instructions2Important safety instructionsSystem• Read this instruction manual.• Keep this instruction manual. Always include this in

Page 35

Sennheiser electronic GmbH & Co. KGAm Labor 1, 30900 Wedemark, Germanywww.sennheiser.comPrinted in GermanyPubl. 01/09529659/A01

Page 36

Important safety instructions3• Danger due to high volumes This device is capable of producing sound pressure exceeding 85 dB(A). 85 dB(A) is thesound

Page 37 - Manufacturer Declarations

The ew 100 G3 evolution wireless series4The ew 100 G3 evolution wireless seriesWith the ew 100 G3 evolution wireless series, Sennheiser offers high-qu

Page 38

Product overview5Product overviewOverview of the EM 100 receiverAB 2 Data Ports auf der Rückseite ergänzen,Anzeigen-Display verkleinern, Jog-Dial entf

Page 39

Product overview6Overview of the displays of the EM 100 receiverAfter switch-on, the receiver displays the standard display “Receiver Parameters”. For

Page 40

Product overview7Overview of the SK 100 bodypack transmitterOperating elements쐃 Microphone/instrument input (MIC/LINE), 3.5 mm jack socket, lockable 쐇

Comments to this Manuals

No comments