Sennheiser EW100 G2 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
Attaching the microphones
Use the microphone clips ! to attach the ME 2 and ME 4 clip-on micro-
phones to clothing (e.g. tie, lapel).
Adjust the ME 3 headmic so that a comfortable and secure fit is ensured.
Positioning the microphones
The ME 3 and ME 4 microphones are directional microphones, i.e. their sound
inlet should always be directed towards the sound source (e.g. mouth).
The ME 2 with omni-directional pick-up pattern picks up sound equally from
all directions. It is the best choice if movements of the speaker’s head have to
be compensated for. However, it should be attached as close as possible to
the sound source.
Adjust the sensitivity correctly for all microphones/usages (see: „Adjusting
the sensitivity (transmitters only)“ on page 32).
SKP 100 G2 plug-on transmitter
Inserting and replacing the batteries
For powering the SKP 100 G2 plug-on transmitter, you can either use two
1.5 V AA size batteries or the rechargeable Sennheiser BA 2015 accupack.
Slide the battery compartment cover in the direction of the embossed
arrow and opern the cover.
Insert the two batteries or the BA 2015 accupack as shown in the diagram
on the left. Please observe correct polarity when inserting the batteries/
accupack.
Close the battery compartment. The battery compartment cover locks
into place with an audible click.
Note:
For accupack operation of the transmitter, only use the BA 2015 accupack
In order to ensure optimum operational reliability. For charging the
accupack, only use the L 2015 charger. Both the accupack and the charger
are available as accessories.
The accupack is fitted with an integrated sensor which is via a third
contact – monitored by the electronics of the transmitter and the charger.
The sensor is necessary for the following control purposes:
y The taking into account of the different voltage characteristics of
primary cells (batteries) and accupacks. The battery status indications
on the displays, the transmission of transmitter battery status
information to the rack-mount receivers and the switch-off thresholds
at the end of the operating time are corrected correspondingly. Due to
the missing sensor, individual rechargeable battery cells will not be
identified as accupacks.
y The monitoring of the accupack temperature during charging in the
L 2015 charger.
!
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 46 47

Comments to this Manuals

No comments