18 | SKP 300 G3
Adjusting settings via the operating menu
Selecting the frequency bank and the channel
manually – “Frequency Preset”
Overview of the frequency banks and channels:
Entering a name – “Name
Via the “Name” menu, you can enter a freely selectable
name for the plug-on transmitter. The name can be
displayed on the standard displays “Frequency/Name
and “Name/Channel” (see page 13) and can consist of
up to 8 characters such as:
letters (without pronounciation marks),
numbers from 0 to 9,
special characters and spaces.
To enter a name, proceed as follows:
When you are in the “Frequency Preset” menu
item, the RF signal is deactivated.
Frequency bank Channels Type
1” to “20 up to 24 per
frequency
bank
System bank:
frequencies are
factory-preset
U1” to “U6 up to 24 per
frequency
bank
User bank:
frequencies are
freely selectable
When setting up multi-channel systems, please
observe the following:
Only the factory-preset transmission frequencies
within one frequency bank (“1” to “20”) are inter-
modulation-free. It is vital to observe the notes on
frequency selection on page 23.
Press the UP/DOWN button to select a
character.
Press the SET button to change to the next
segment/character or to store the complete
entry.
Menu
B.Ch:
18.24
Frequency Preset
B.Ch:
546.550MHz
Frequency Preset
18.24
B.Ch:
Frequency Preset
19.24
Call up “Frequency
Preset”
Select the frequency
bank and confirm
Select the channel;
store the setting
“Stored”
538.475MHz
Call up “Name” Enter a character
and confirm
Enter a character;
store the setting
Menu
Lichael
Name
Name
Name
L ichael
Michael
“Stored”
SET
Page view 18