Sennheiser EM 500 G3 Instruction Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
24
Specifications
Specifications
In compliance with
RF characteristics
Modulation wideband FM
Frequency ranges 516–558, 566–608, 626–668,
734–776, 780–822,
823–865 MHz
(A to E, G, seepage3)
Transmission frequencies 1,680 frequencies, tuneable in
steps of 25 kHz
20 frequency banks, each
with up to 32 factory-preset
channels
6 frequency banks with up
to 32 user programmable
channels
Switching bandwidth 42 MHz
Nominal/peak deviation ±24 kHz/±48 kHz
Frequency stability ±15 ppm
RF output power at 50 Ω,
switchable
typ. 10 mW (low)
typ. 30 mW (standard)
Pilot tone squelch can be switched off
AF characteristics
Compander system Sennheiser HDX
AF frequency response microphone: 80–18,000 Hz
line: 25–18,000 Hz
Signal-to-noise ratio
(1 mV, peak deviation) 115 dBA
THD 0.9%
Max. input voltage 3 V
rms
Input impedance 40 kΩ, unbalanced/1 MΩ
Input capacitance switchable
Adjustment range of input sensitivity 60 dB,
adjustable in 3-dB steps
Overall device
Temperature range 10°C to +55°C
Power supply
2
AA size batteries, 1.5 V
or BA 2015 accupack
Nominal voltage 2.4 V
Power consumption
at nominal voltage typ. 180 mA (30 mW)
with switched-off transmitter 25 μA
Operating time typ. 8 hrs
Dimensions approx. 82 x 64 x 24 mm
Weight (incl. batteries) approx. 160 g
Europe EMC EN 301489-1/-9
Radio EN 300422-1/-2
Safety EN 60065,
EN 62311 (SAR)
Page view 25