Sennheiser EM 3532-U Service Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
66

24 Sennheiser transmitters report their battery status
Sennheiser supplies hand-held and pocket transmitters which provide information on the available
transmitter battery status to the receiver. This information can be evaluated with the EM 3532
receiver.
The remaining battery capacity is first indicated via the six-step bargraph on the display
panel .
When the battery capacity is so low that only a transmission time of about 20 to 30 minutes
remains, the “LOW BATT” display flashes on the display panel .
You should now immediately replace the transmitter battery. The AMF (
Advanced Muting
Function) in the EM 3532 receiver helps you, as far as possible, to maintain the transmission
without noise.
Notes
The “LOW BATT” display is reset by the mute function. Whenever the squelch is activated
in the receiver, the “
LOW BATT” display goes off and the evaluation of the battery status
signal from the transmitter starts over again.
Under favourable reception conditions, the evaluation of the battery information from the
transmitter lasts about 10 – 20 seconds. However, it can be significantly longer if reception
is subject to interference from time to time. This time is then also needed by the display in
display panel
in order to update the information shown.