19
Adjusting settings via the operating menu
The extended menu “Advanced Menu
Setting transmission frequencies and frequency banks – “Tune”
When you have selected one of the system banks and then select the
Tune” menu, the bodypack transmitter automatically switches to
channel 1 of the frequency bank “U1”. In this case, “U1.1” briefly appears
on the display panel. Upon delivery, the channels of the frequency banks
U1” to “U6” are not assigned a transmission frequency.
When you are in the “Tune” menu item, the RF signal is deactivated. Via
the “Tune” menu item, you can set a transmission frequency to be stored
in the current channel or you can select a different channel in one of the
frequency banks “U1” to “U6” and assign this channel a transmission
frequency. It is vital to observe the notes on frequency selection on
page 22.
Setting a transmission frequency for the current channel
Set the desired frequency.
Selecting a channel and assigning this channel a frequency
Set the desired frequency bank and the desired channel.
Set the desired frequency.
Press the rocker button until the “Tune” menu item appears.
Press the SET button.
The frequency selection appears.
Press the SET button.
Your settings are stored.
You are back to the operating menu.
Press the rocker button until the “Tune” menu item appears.
Press the SET button until the frequency bank selection
appears.
Press the SET button.
The frequency selection appears.
SET
Select the MHz
value and confirm
Select the kHz
value; store the
setting
543 .200 MHz
Tune
544.200 MHz
B.Ch: 20.1 B.Ch: 20.1
Tune
Call up
“Tune”
Advanced
Menu
Tune
“Stored”
SET SET
SET
543.200 MHz
SET
SET
Select the
frequency bank
and confirm
Select the channel;
store the setting
Tune
B.Ch: U1. 1 B.Ch: U1. 1
Tune
Call up “Tune”
(special function)
Advanced
Menu
Tune
“Stored”
543.200 MHz
SET
SET
SET
SET