Sennheiser Rack-mount Receiver EM 300 G3 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Putting the receiver into operation
14
Mounting the receiver into a 19” rack
Rack mounting
one receiver
Secure the rack mount “ears” of the supplied GA 3 rack adapter to
the receiver as described on page 12.
Secure the blanking plate of the supplied GA 3 rack adapter to one
of the rack mount “ears” using two recessed head screws (M 6x10).
Do not fit the device feet when mounting the receiver into a
19” rack.
CAUTION! Risks when rack mounting the receiver!
When installing the device in a closed or multi-rack assembly, please
consider that, during operation, the ambient temperature, the mechanical
loading and the electrical potentials will be different from those of devices
which are not mounted into a rack.
Make sure that the ambient temperature within the rack does not
exceed the permissible temperature limit specified in the specifications
(see page 54).
Ensure sufficient ventilation; if necessary, provide additional ventila-
tion.
Make sure that the mechanical loading of the rack is even.
When connecting to the power supply, observe the information indi-
cated on the type plate. Avoid circuit overloading. If necessary, provide
overcurrent protection.
When rack mounting, please note that intrinsically harmless leakage
currents of the individual mains units may accumulate, thereby
exceeding the allowable limit value. As a remedy, ground the rack via an
additional ground connection.