Configuring the conference system via the central unit
38
System analysis – “Diagnostics” submenu
The “Diagnostics” menu item provides information on the status of the current and
voltage supply, on the status of data transmission and on interruptions due to
faulty cables or cable connections.
Displaying status information on the
current and
voltage supply –
“System Load”
Both ports can be subjected to undervol
tages, overcurrents and short-circuits:
If an error icon appears (see page 34), check your conference system for the errors
mentioned above.
Possible steps for error elimination:
Eliminate the errors separately for each port.
Calculate the maximum length of the cable string (see page 13) and, if neces-
sary, reduce the cable length.
Reduce the number of conference units to 15-20
max. per cable string.
Select and call up the
“System” submenu
Select and call up the
“Diagnostics” submenu
The “Diagnostics”
submenu appears
Main Menu
Conference
Audio
System
System
Ports
Diagnostics
Versions
System Load
Temperature
Bus Statistics
Diagnostics
No No
Display Meaning and causes
Current
An overcurrent in the central unit can be caused by
metal parts (e.g. paper clips) that bridge the contacts of the plug
connections
faulty conference units
faulty system cables
too long system cables
too many conference units connected to one port
Voltage
An undervoltage can be caused by
faulty conference units
too long system cables
too many conference units connected to one port
Current A short-circuit in the central unit can be caused by e.g.
metal parts (e.g. paper clips) that bridge the contacts of the plug
connections
faulty system cables
wrong cables (e.g. crossover cables)
Voltage
--
The port is deactivated due to e.g.
no conference units connected
a short-circuit
If an error is detected at startup of the central unit, first eliminate the
error and then perform a manual self-test (see page 40) in order to check
if the error still occurs.
If an error has only occured during operation and has already been elim-
inated, this is automatically detected by the central unit.
Select and call up the
“Diagnostics” submenu
Select and call up the
“Load” menu item
View the information;
exit the menu item
Diagnostics
System Load
Temperature
Bus Statistics
Load
No No
Main Menu
System
Diagnostics
Current Voltage
Port 1
Port 2 – –