Configuring the conference system via the central unit
If necessary, further reduce the number of conference units until there are no
errors reported.
Then add conference units one after
the other and observe the central unit’s
display. If an error is reported, the cause of the error might be the last added
conference unit, the cable used or metal parts that bridge the contacts of the
plug connection.
Displaying the temperature status –
“T
em
perature”
If the temperature within the central u
nit is too high (display: “ ”), proceed as
follows:
Make sure that the air vents are not covered or blocked (see page 15).
If necessary, clean the air vents (see page 104).
If the central unit is mounted into a rack:
Provide additional ventilation by providing for a clearance below the central
uni
t
and/or installing additional fans into the rack.
When the temperature is again within the
permissible temperature range, this
is automatically detected by the central unit (display: ”). The temperature
check is carried out cyclically.
If, in spite of these measures, the temperature is still detected to be too high, one
of the fans might de faulty:
Have the fans checked and, if necessary, replaced by qualified maintenance
pe
rso
nnel.
Displaying system bus errors –
“Bus
Statistics”
Possible causes for system bus errors are:
changes in the number of conference units
faulty cables
faults in cable shields
faulty conference units
strong electromagnetic fields
If there are system bus errors, the “ ” icon appears behind “Error Indication”.
The display panel lights up red and the warning triangle is displayed on the
standard display (see page 34).
There are temporary or permanent transmission errors:
Temporary transmission errors can be caused by e.g. poorly shielded mobiles
phones that
are placed too close to the system cables or conference units. If the
transmission error no longer exists, the ” icon appears on the display. The
display panel lights up orange and the warning triangle goes off.
Select and call up the
“Diagnostics” submenu
Select and call up
the “Temperature”
menu item
View the information;
exit the menu item
Diagnostics
System Load
Temperature
Bus Statistics
Temperature
No No
Main Menu
System
Diagnostics
Status
Select and call up the
“Diagnostics” submenu
Select and call up
the “Bus Statistics”
menu item
View the information;
exit the menu item
Diagnostics
Load
Temperature
Bus Statistics
Bus Statistics
No No
Main Menu
System
Diagnostics
Error Indication :
Break Counter : 1
N
N