Possible expansion stages
30
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Example 2:
The 25 conference consoles that can be powered via the central unit are
split up into three different strings:
String I: 10 conference consoles
String II: 7 conference consoles
String III: 8 conference consoles
To power the subsequent conference consoles, you must add an exter-
nal power supply to each string. You can then connect 25 additional
consoles per string.
Expansion stage (4): up to 600 conference consoles
You can connect a maximum of three cable strings with up to 50 consoles
each to one central unit. For larger conference systems with up to 600
conference consoles, a total of four central units is required. The additional
central units are connected as “slaves” to the central unit configured as
“master” (see “Interconnecting up to four central units” on page 44). If
the conference system is to be PC controlled, the PC must be connected to
the “master” central unit.
To set up a conference system with up to four central units, you first have
to interconnect the cable strings of each central unit as described for
conference systems of expansion stage (3) (see Expansion stage (3): up
to 150 conference consoles” on page 29). The distance between a central
unit and the first conference console or the first power supply of a cable
string must not exceed 80 m. The distance between a central unit and the
last conference console of a cable string must not exceed 230 m.
The maximum length of the system cables used for interconnecting the
central units must not exceed 3 m.
230 m
3 m
1
2
7
8
3 m
3 m
32
...
...
3 m
1
2
10
11
3 m
3 m
35
...
...
3 m
1
2
8
9
3 m
3 m
33
...
...
10 m
5 m
80 m
I
II
III