44
Technical data
HME 100 HME 105 and HME 120 HMD 120
Headphones
Transducer principle dynamic
Ear coupling circumaural, closed
Frequency response 45–15,000 Hz
Nominal impedance 150 Ω, mono, 300 Ω, stereo 150 Ω, mono 16 Ω, mono
Attenuation > 10–40 dB
Contact pressure approx. 10 N
Microphone incl. preamplifier
Transducer principle electret mic capsule, electret mic capsule, dynamic,
noise-compensated noise-compensated noise-compensated
MKE 45-1 MKE 45-1 M-87/AIC
Frequency response 300–5,000 Hz 300–5,000 Hz 500–4,000 Hz
Sensitivity – – 1.8–4 µV/74 dB bei 5 Ω
Max. sound pressure level 120 dB 120 dB –
Min. terminating impedance 150 Ω 150 Ω –
Output voltage 400 mV ± 3dB 400 mV ± 3dB –
at 114 dB at 114 dB
(as per RTCA/DO 214) (as per RTCA/DO 214)