Sennheiser Microphone SDC 8200 User Manual Page 121

  • Download
  • Add to my manuals
  • Print
  • Page
    / 128
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 120
Appendix A: Camera control protocol
121
C
omman
d
s:
Notation of the general syntax:
All separate entities in a message are represented between curly brackets, e.g.
{CRC}
Literal strings are between quotes, e.g. 'P'
Logical entities are neither between brackets nor quotes, e.g. Mic.-No. (microphone number)
A logical entity will also contain a number between brackets. This number states how many characters the entity exists of, e.g.
(4)
If the subtext
1+
is attached to the entity between curly brackets, this means that one or more occurrences of this entity may occur
General syntax General meaning Examples
{'%'}{'1'}{'R'}{'00'}{CRC(4)}
The first microphone is activated.
%1R0053
The first microphone is activated.
The camera control is activated.
{'%'}{'P'}{Mic.-No.(4)}{CRC(4)}
The chairman unit is activated.
%P00010111
The chairman unit is activated and it has the
microphone number '0001'.
{'%'}{'p'}{Mic.-No.(4)}{CRC(4)}
The chairman unit is deactivated.
%p00010131
The chairman unit '0001' is deactivated.
{'%'}{'M'}{Mic.-No.(4)}{CRC(4)}
A delegate unit is activated.
%M00030110
A delegate unit is activated and it has the micro-
phone number '0003'.
{'%'}{'m'}{Mic.-No.(4)}{CRC(4)}
A delegate unit is deactivated.
%m00030130
The delegate unit '0003' is deactivated.
{'%'}{'1'}{'r'}{'00'}{CRC(4)}
All active microphones are deactivated and the
camera control should reset itself to a neutral
starting position.
%1r000052
The camera control should reset itself to its start-
ing position.
{'%'}{'S'}{Mic.-No.(4)}1+{CRC(4)}
At a time interval of approx. 5 seconds, a synchro-
nization message is sent to the camera control.
The message contains all the numbers of the
active microphones or the number 0 to stipulate
that there are no microphones active.
%S00030116
Synchronization check while only the delegate unit
with the microphone number '0003' is active.
%S000200030004029C
Synchronization check while the delegate units
'0002', '0003' and '0004' are active.
{'%'}{'S'}{0(4)}{CRC(4)} %S00000113
No microphones are active.
{'%'}{'V'}{'0000'}{CRC(4)}
All active microphones are deactivated simulta-
neously.
%V00000116
All active microphones are deactivated simulta-
neously.
Page view 120

Comments to this Manuals