If a problem occurs ...
106
If a problem occurs ...
Conference system
Problem Possible cause Possible solution Page
Central unit cannot be
switched on
The central unit is not connected to
the mains.
Connect the central unit to the mains. 16
Conference unit cannot be
used/activated
The conference unit is not connected
correctly.
Check if all plugs are connected
correctly.
17
The cable string is too long. Reduce the length of the cable string
or reduce the number of conference
units.
13
The maximum number of requests to
speak has been reached.
Increase the maximum number of
requests to speak.
28 or 91
The chairman unit has not been initial-
ized before use.
If chairman units are connected after-
wards, you have to initialize them.
30 or 88
The central unit’s display
panel displays error icons/
the display panel lights up
red
Changes or errors have occurred. Check the possible causes indicated by
the icons.
34
Volume of the conference
units’ loudspeakers is too
high or too low
The processing of the conference
units’ audio signals (“Audio Gain
Reduction
”) is adjusted so that the
gain of each additional channel is
reduced too much or too little.
Adjusting the processing of the
conference units’ audio signals.
32 or 94
The floor channel volume is not
adjusted correctly.
Adjust the floor channel volume. 48, 93 or
101
Loud hissing at the confer-
ence units’ loudspeakers
The conference units are placed too
close together.
Increase the distance between the
individual conference units to at least
50
cm.
The floor channel volume is adjusted
to a very high level.
Reduce the floor channel volume. 48, 93 or
101
After switch-on, the dele-
gate units only indicate
requests to speak
You are using ADN D1 delegate units
exclusively. The conference mode
chosen requires a chairman unit
for granting speaking privileges
(e.g
.Request
”).
Set a conference mode which does
not
require the grant of speaking
privileges.
26 or 90
Use an ADN C1 chairman unit to assign
the “speaking right.
47
Use the “Conference Manager”
software to grant speaking privileges.
99
Delegate unit is automati-
cally deactivated
The speaking time limit is activated. Deactivate or increase the speaking
time limit.
28 or 91
A further speaker has made a request
to speak in “Override” mode.
Change the conference mode. 26 or 90
Increase the number of speakers who
can take the floor simultaneously.
27 or 91
No request to speak can be
made
The maximum number of requests to
speak has been reached.
Increase the maximum number of
requests to speak.
28 or 91
Wait until one of the current speakers
passes on his or her speaking privi-
leges.
The signal light ring
does not flash when a
request to speak is made
The function is deactivated. Activate the function. 30 or 91