Configuring the SDC 8200 system
109
The row marked in grey shows the factory-preset standard configuration.
The column marked in grey shows the reference output OUT 1 and the
channel numbers assigned.
Example:
Your system accommodates 16 interpretation channels and you want
to output each interpretation channel via its own audio output. To do
so, you require two analog output units whose outputs have to be con-
figured as follows:
The factory-preset standard configuration of the first analog output
unit remains unchanged (the channels 1 to 8 are output via the unit’s
outputs OUT 1 to OUT 8, the floor channel is output via output OUT 0).
Make sure that the second analog output unit is not connected!
Open the second analog output unit by removing the seven screws on
the top of the housing as well as the screw on the front panel with a
2.0 mm Allan key and lift the cover off the unit.
Leave the two DIP switches in position “OFF” as shown in the illustra-
tion on the left.
Use a screwdriver to set the rotary switch to position “9”.
Close the housing and tighten the screws. In order to avoid that the two
analog output units are later confused, we recommend marking the
second analog output unit with a sticker.
Connect the second analog output unit as described in the section
“Connecting several SDC 8200 AO analog output units to the SDC 8200
CU central unit” on page 58.
The channels 9 to 16 are output via the outputs OUT 1 to OUT 8 of the
analog output unit. The floor channel is output via the unit’s output
OUT 0.
Making a system diagnosis
Displaying the current port status
To display the status of the individual ports:
From the central unit’s operating menu, choose “
System”,
Diagnostics” and “Port Status” one after the other and press the
ENTER key.
The display shows the ports “
P1“ to “P6“ with symbols indicating
whether or not a cable string with consoles is connected.
The symbols have the following meanings:
: A cable string with consoles is connected to the port.
: No cable string is connected to the port. If this symbol appears even
though a cable string is connected to the port, check if the cable string
is connected correctly.
ON
1
2
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Diagnostics
1 Port Status
Port Status
P1 P2 P3 P4 P5 P6