Possible expansion stages
28
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Instead of interconnecting 25 consoles in one string, you can also split up
the consoles into three different strings:
Example 2:
The central unit’s integrated power supply can power up to 25 consoles
which can be split up into three different strings:
1. string: 10 conference consoles
2. string: 7 conference consoles
3. string: 8 conference consoles
The distances between the central unit and the first conference
console of a string can vary or not, but the maximum distance of 80m
must not be exceeded. The length of the system cables between two
consoles is typically 3 m so that one cable string is not longer than
155 m.
152 m
3 m
80 m
1
2
325
...
155 m
10 m
1
2
7
...
3 m
1
2
10
...
1
2
8
...
3 m
80 m
3 m
3 m
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 125 126

Comments to this Manuals

No comments